高頻寬 50/125 多模光纖(50/125/250μm PrimeLaser™ 300 fiber)

♦  This specification conforms to the requirement of IEC 60793 A1a, IEC 11801OM3
    and ITU-T G.651.
♦  OM3-type 850 nm Laser-Optimized 50 µm Multimode Fiber for 10 Gb/s
    Application over 300 m
 

OPTICAL CHARACTERISTICS
Characteristics
Conditions
Specified Values
Unit
Attenuation Coefficient
850 nm
≦ 2.5
〔dB/km〕
 
1300 nm
≦ 0.7
〔dB/km〕
Numerical Aperture
 
0.200 ± 0.015
 
Overfilled Modal Bandwidth
850 nm
≧ 1500
〔MHz·km〕
 
1300 nm
≧ 500
〔MHz·km〕
Differential Mode Delay
850 nm
Any one of the following masks:

 Note:
 A minimum effective system modal bandwidth-  length product of 2000 MHz·km is achieved 
 when combining this 50µm fiber with
 transmitters meeting the following transmitter
 power distribution (per FOTP-203):
 Encircled Flux at radius 4.5µm:≦30% and
 Encircled Flux at radius 19µm:≧86%
 (Ref.:TIA/EIA-492AAAC,ISO/IEC 11801)
 
DMD Mask
DMD Inner Range
(Radius 5 to 18 µm)
〔ps/m〕
DMD Total Range
(Radius 0 to 23 µm)
〔ps/m〕
1
≦ 0.23
≦ 0.70
2
≦ 0.24
≦ 0.60
3
≦ 0.25
≦ 0.50
4
≦ 0.26
≦ 0.40
5
≦ 0.27
≦ 0.35
6
≦ 0.33
≦ 0.33

BACKSCATTER CHARACTERISTICS
Attenuation Directional Uniformity
≦ 0.05
〔dB/km〕
Attenuation Uniformity
 
≦ 0.05
〔dB〕     
Group Index of Refraction
850 nm
1.481
 
 
1300 nm
1.476
 
 
PHYSICAL CHARACTERISTICS
Core Diameter 50.0 ± 2.5 〔µm〕
Core Non- circularity ≦ 5 〔%〕
Core / Cladding Concentricity Error
≦ 1.5
〔µm〕
Cladding Diameter
 
125 ± 1
〔µm〕
Cladding Non-Circularity
 
≦ 1.0
〔%〕
Coating Diameter
245 ± 10
〔µm〕
Coating Non-Circularity
 
≦ 6
〔%〕
Clad/Coat Concentricity Error
 
≦ 5
〔µm〕
Fiber curl
 
≧ 4
〔m〕
Proof Test
 
100
〔kpsi〕
Bend Induced Attenuation at 1300 nm
≦ 0.5
〔dB〕
(100 turns around a mandrel of 75 mm diameter)
 
 
Coating Strip Force (Typical)
130
〔g〕
Length (Typical)
 
4.4~8.8
〔km〕
 
ENVIRONMENTAL CHARACTERISTICS
Temperature Dependence at 850 nm and 1300 nm
≦ 0.1
〔dB/km〕
  Induced Attenuation – 60°C to +85°C
 
 
Temperature And Humidity Cycling at 850 nm and 1300 nm
≦ 0.2
〔dB/km〕
  Induced Attenuation at -10°C to +85°C , 90%R.H
 
 
Watersoak Dependence at 850 nm and 1300 nm
≦ 0.2
〔dB/km〕
  Induced Attenuation at 23°C for 30 days
 
 
Damp Heat Dependence at 850 nm and 1300 nm
≦ 0.2
〔dB/km〕
  Induced Attenuation at 85°C, 85%R.H., 30 days